| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.437 INCHES NOMINAL ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 1.422 INCHES NOMINAL ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.400 INCHES NOMINAL ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.630 INCHES NOMINAL ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.551 INCHES NOMINAL ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | COVER TYPE ALL FLANGES |
| FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
| OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| MATERIAL | COPPER ALLOY FIRST TUBING SEGMENT AND FLANGE |
| MATERIAL | RUBBER SILICONE SECOND TUBING JACKET |
| PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |
| PRECIOUS MATERIAL | SILVER |
| TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
| WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES NOMINAL |
| WAVEGUIDE INSIDE WIDTH | 0.900 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.506 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE WIDTH | 1.630 INCHES NOMINAL |
| WAVEGUIDE LENGTH | 5.875 INCHES NOMINAL |
| SPECIFIED FREQUENCY | 8.2 GIGAHERTZ MINIMUM AND 12.4 GIGAHERTZ MAXIMUM |
| STYLE DESIGNATOR | STRAIGHT TYPE |
| SURFACE TREATMENT | SILVER ALL TUBING SEGMENT INSIDE SURFACES |