| BEND ANGLE IN DEG | 90.0 FIRST BEND H-PLANE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.121 INCHES MINIMUM AND 0.126 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | RIGID ALL TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS, WAVEGUIDES, AND RELATED EQUIPMENT |
| INSERTION LOSS IN DECIBELS | 0.10 |
| MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT |
| OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| VOLTAGE STANDING WAVE RATIO | 1.20 |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 10.271 INCHES MINIMUM AND 10.287 INCHES MAXIMUM |
| WAVEGUIDE HEIGHT | 9.841 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.6195 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM |
| STYLE DESIGNATOR | DOUBLE BEND TYPE |
| SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT ALL SURFACES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |