| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| INSERTION LOSS IN DECIBELS | 0.07 |
| OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
| WAVEGUIDE FIRST LEG LENGTH | 1.630 INCHES NOMINAL |
| WAVEGUIDE FOURTH LEG LENGTH | 9.500 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
| WAVEGUIDE SECOND LEG LENGTH | 9.250 INCHES NOMINAL |
| WAVEGUIDE THIRD LEG LENGTH | 15.180 INCHES NOMINAL |
| STYLE DESIGNATOR | THREE BEND TYPE |
| SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |