| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR DOUBLE INDENTED |
| FLANGE DEPTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 2 THREADED HOLE(S) FIRST FLANGE FIRST CONNECTION FACILITY |
| FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE(S) FIRST FLANGE SECOND CONNECTION FACILITY |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) SECOND FLANGE ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.145 INCHES MINIMUM AND 0.148 INCHES MAXIMUM FIRST FLANGE SECOND CONNECTION FACILITY |
| FLANGE CONNECTING HOLE DIAMETER | 0.145 INCHES MINIMUM AND 0.148 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| INSERTION LOSS IN DECIBELS | 0.15 |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE FIRST CONNECTION FACILITY |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| TUBING TWIST ANGLE IN DEG | 90.0 SINGLE TUBING SEGMENT |
| TUBING TWIST TYPE | STRAIGHT TWIST SINGLE TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.15 |
| WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
| WAVEGUIDE LENGTH | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
| STYLE DESIGNATOR | STRAIGHT TYPE |
| SURFACE TREATMENT | CHROMATE AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| THREAD CLASS | 2B FIRST FLANGE FIRST CONNECTION FACILITY |
| THREAD DIRECTION | RIGHT-HAND FIRST FLANGE FIRST CONNECTION FACILITY |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) FIRST FLANGE FIRST CONNECTION FACILITY |
| THREAD QUANTITY PER INCH | 32 FIRST FLANGE FIRST CONNECTION FACILITY |