| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | FLEXIBLE FIRST TUBING SEGMENT |
| FLEXIBILITY | RIGID SIXTH TUBING SEGMENT |
| FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
| FLEXIBILITY | RIGID FIFTH TUBING SEGMENT |
| FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
| FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
| FSC APPLICATION DATA | RADAR EQUIPMENT |
| INSERTION LOSS IN DECIBELS | 0.10 |
| MATERIAL | ALUMINUM ALL TUBING SEGMENT AND FLANGE |
| OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| SPECIAL FEATURES | FREQUENCY RANGE 2.85 GHZ TO 3.05 GHZ |
| VOLTAGE STANDING WAVE RATIO | 1.12 |
| WAVEGUIDE OFFSET DISTANCE | 12.350 INCHES MINIMUM AND 12.410 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 1.500 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE WIDTH | 3.000 INCHES NOMINAL |
| WAVEGUIDE INSIDE HEIGHT | 1.340 INCHES NOMINAL |
| WAVEGUIDE INSIDE WIDTH | 2.840 INCHES NOMINAL |
| WAVEGUIDE LONGER OFFSET DISTANCE | 16.680 INCHES MINIMUM AND 16.740 INCHES MAXIMUM |
| STYLE DESIGNATOR | BEND TYPE |
| SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |