5985-01-326-8513 WAVEGUIDE ASSEMBLY Index 5850-01-326-8515 LENS,LIGHT

National Stock Number:
5985-01-326-8514

Federal Supply Class:
5985

National Item Identification Number:
013268514

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
697422-2115305OMEGA LABORATORIES INC
697422-2198897LOCKHEED MARTIN CORP


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE(S) FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE(S) SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE DIAMETER1.406 INCHES MINIMUM AND 1.437 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM SECOND FLANGE
FLANGE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATARADAR EQUIPMENT
INSERTION LOSS IN DECIBELS0.50
OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM
MATERIALALUMINUM ALL TUBING SEGMENT AND FLANGE
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
VOLTAGE STANDING WAVE RATIO1.25
WAVEGUIDE LONGER OFFSET DISTANCE35.670 INCHES MINIMUM AND 35.730 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
STYLE DESIGNATORBEND TYPE
SURFACE TREATMENTCHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) FIRST FLANGE ALL CONNECTION FACILITIES


Click here to Register for Free 30-day Trial