| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE CONNECTING FACILITY AND QUANTITY | 8 THREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
| INSERTION LOSS IN DECIBELS | 0.06 |
| MATERIAL | ALUMINUM ALLOY ALL FLANGE |
| MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT |
| NOMINAL THREAD SIZE | 0.190 INCHES ALL FLANGES ALL CONNECTION FACILITIES |
| OPERATING PRESSURE | 35.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| VOLTAGE STANDING WAVE RATIO | 1.08 |
| WAVEGUIDE OFFSET DISTANCE | 2.500 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 1.494 INCHES MINIMUM AND 1.506 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 2.994 INCHES MINIMUM AND 3.006 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 1.334 INCHES MINIMUM AND 1.346 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 2.834 INCHES MINIMUM AND 2.846 INCHES MAXIMUM |
| WAVEGUIDE LONGER OFFSET DISTANCE | 10.460 INCHES NOMINAL |
| STYLE DESIGNATOR | BEND TYPE |
| SURFACE TREATMENT | PRIMER AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| THREAD DIRECTION | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
| THREAD SERIES DESIGNATOR | UNF ALL FLANGES ALL CONNECTION FACILITIES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |