| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.166 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 1.297 INCHES MINIMUM AND 1.327 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.630 INCHES MINIMUM AND 0.633 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | COVER TYPE ALL FLANGES |
| FLEXIBILITY | RIGID ALL TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIP. |
| MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
| SPECIAL FEATURES | CONSISTS OF TWO STRAIGHT PIECES AND ONE BEND WITH ATTACHED MOUNTING BRACKET 2.000 IN. BY 0.750 IN.,2 HOLES 0.265 IN. DIA THRU SPACED 1.500 IN. EQUALLY |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.226 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| WAVEGUIDE LONGER OFFSET DISTANCE | 2.933 INCHES MINIMUM AND 2.943 INCHES MAXIMUM |
| WAVEGUIDE OFFSET DISTANCE | 1.870 INCHES MINIMUM AND 1.880 INCHES MAXIMUM |
| STYLE DESIGNATOR | BEND TYPE |
| SUPPLEMENTARY FEATURES | DIP BRAZE IAW MIL-B-7883,TYPE 5,GRADE B |