| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM SECOND FLANGE |
| FLANGE DEPTH | 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM FIRST FLANGE |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE(S) FIRST FLANGE ALL CONNECTION FACILITIES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) SECOND FLANGE ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 1.218 INCHES MINIMUM AND 1.226 INCHES MAXIMUM FIRST FLANGE |
| FLANGE INSIDE WIDTH | 1.253 INCHES MINIMUM AND 1.256 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE DIAMETER | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE |
| FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM FIRST FLANGE |
| FLANGE INSIDE HEIGHT | 0.628 INCHES MINIMUM AND 0.631 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
| FLANGE STYLE | COVER TYPE SECOND FLANGE |
| FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
| FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES AND RELATED EQUIP. |
| MATERIAL | ALUMINUM ALLOY FIRST TUBING SEGMENT |
| MATERIAL | COPPER ALLOY ALL FLANGE |
| MATERIAL | COPPER ALLOY SECOND TUBING SEGMENT |
| NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 2.280 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| WAVEGUIDE LENGTH | 4.090 INCHES NOMINAL |
| STYLE DESIGNATOR | OFFSET BEND TYPE |
| SURFACE TREATMENT | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) FIRST FLANGE ALL CONNECTION FACILITIES |
| TUBING WALL CONSTRUCTION STYLE | CORRUGATED SECOND TUBING SEGMENT |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |