| BEND ANGLE IN DEG | 90.0 FIRST BEND E-PLANE |
| BEND ANGLE IN DEG | 95.0 FIRST BEND H-PLANE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.438 INCHES NOMINAL FIRST FLANGE |
| FLANGE DEPTH | 0.438 INCHES NOMINAL SECOND FLANGE |
| FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE WIDTH | 1.062 INCHES NOMINAL FIRST FLANGE |
| FLANGE INSIDE HEIGHT | 0.399 INCHES MINIMUM AND 0.402 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM AND 0.506 INCHES MAXIMUM FIRST FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL FIRST FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL SECOND FLANGE |
| FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL FIRST FLANGE |
| FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL SECOND FLANGE |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
| FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
| FLEXIBILITY | FLEXIBLE FIRST TUBING SEGMENT |
| FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
| FSC APPLICATION DATA | WAVEGUIDE INSTALLATION X-BAND WEATHER RADAR |
| INSERTION LOSS IN DECIBELS | 0.40 |
| MATERIAL | ALUMINUM SECOND TUBING SEGMENT |
| MATERIAL | COPPER ALLOY FIRST TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.08 |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 9.740 INCHES MINIMUM AND 9.860 INCHES MAXIMUM |
| WAVEGUIDE HEIGHT | 14.235 INCHES MINIMUM AND 14.355 INCHES MAXIMUM |
| WAVEGUIDE LEG LENGTH | 4.655 INCHES MINIMUM AND 4.775 INCHES MAXIMUM |
| WAVEGUIDE LONGER LEG LENGTH | 10.520 INCHES MINIMUM AND 10.640 INCHES MAXIMUM |
| STYLE DESIGNATOR | U-BEND TYPE |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |