Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
SM-D-952497-180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
STYLE DESIGNATORBEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY6 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE STYLECOVER TYPE ALL FLANGES
FLEXIBILITYRIGID ALL TUBING SEGMENT
MATERIALCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
WAVEGUIDE LONGER OFFSET DISTANCE4.115 INCHES MINIMUM AND
4.135 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE2.270 INCHES MINIMUM AND
2.290 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.496 INCHES MINIMUM AND
1.504 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.368 INCHES MINIMUM AND
1.376 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.618 INCHES MINIMUM AND
0.626 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.746 INCHES MINIMUM AND
0.754 INCHES MAXIMUM
SURFACE TREATMENTPAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH1.502 INCHES MINIMUM AND
1.508 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.752 INCHES MINIMUM AND
0.758 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE DIAMETER3.110 INCHES MINIMUM AND
3.140 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.360 INCHES MINIMUM AND
0.390 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.195 INCHES MINIMUM AND
0.203 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
VOLTAGE STANDING WAVE RATIO1.10
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT