5985-01-099-5941 WAVEGUIDE ASSEMBLY Index 5985-01-099-5944 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-099-5942

Federal Supply Class:
5985

National Item Identification Number:
010995942

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
SM-D-952414-180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY6 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE STYLECOVER TYPE FIRST FLANGE
CONTACT TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
WAVEGUIDE OUTSIDE WIDTH1.496 INCHES MINIMUM AND
1.504 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.368 INCHES MINIMUM AND
1.376 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.618 INCHES MINIMUM AND
0.626 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.746 INCHES MINIMUM AND
0.754 INCHES MAXIMUM
SURFACE TREATMENTPAINT ALL TUBING SEGMENT OUTSIDE SURFACES
FLANGE INSIDE WIDTH1.505 INCHES MINIMUM AND
1.508 INCHES MAXIMUM FIRST FLANGE
1.368 INCHES MINIMUM AND
1.376 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE HEIGHT0.755 INCHES MINIMUM AND
0.758 INCHES MAXIMUM FIRST FLANGE
0.618 INCHES MINIMUM AND
0.626 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH2.670 INCHES MINIMUM AND
2.710 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.920 INCHES MINIMUM AND
1.960 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE DIAMETER3.110 INCHES MINIMUM AND
3.140 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.360 INCHES MINIMUM AND
0.390 INCHES MAXIMUM FIRST FLANGE
0.480 INCHES MINIMUM AND
0.520 INCHES MAXIMUM SECOND FLANGE
FLANGE CONNECTING HOLE DIAMETER0.199 INCHES MINIMUM AND
0.203 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES
0.196 INCHES MINIMUM AND
0.200 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
VOLTAGE STANDING WAVE RATIO1.05
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT


Click here to Register for Free 30-day Trial