5975-01-097-7303 JUNCTION BOX Index 5985-01-097-7306 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-097-7305

Federal Supply Class:
5985

National Item Identification Number:
010977305

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
1143757706351MICROWAVE ENGINEERING CORPORATION
1143757718876U S ARMY AVIATION AND MISSILE COMMAND
4743652564MEGA INDUSTRIES INC MEGA MICROWAVE DIV
1143757781482PAGE CHESTER LTD


Techincal Specification:
STYLE DESIGNATORBEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLECORRUGATED SINGLE TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
MATERIALRUBBER SINGLE TUBING JACKET
WAVEGUIDE LONGER OFFSET DISTANCE7.690 INCHES MINIMUM AND
7.810 INCHES MAXIMUM
WAVEGUIDE LENGTH9.310 INCHES NOMINAL
WAVEGUIDE OFFSET DISTANCE3.660 INCHES MINIMUM AND
3.780 INCHES MAXIMUM
WAVEGUIDE CENTER TO CENTER DISTANCE1.250 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH1.995 INCHES MINIMUM AND
2.005 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.867 INCHES MINIMUM AND
1.877 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.867 INCHES MINIMUM AND
0.877 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.995 INCHES MINIMUM AND
1.005 INCHES MAXIMUM
TUBING TWIST TYPESTRAIGHT TWIST SINGLE TUBING SEGMENT
SURFACE TREATMENTCOPPER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH1.867 INCHES MINIMUM AND
1.877 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.867 INCHES MINIMUM AND
0.877 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH3.480 INCHES MINIMUM AND
3.520 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT2.480 INCHES MINIMUM AND
2.520 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.670 INCHES MINIMUM AND
0.710 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.257 INCHES MINIMUM AND
0.262 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
MAXIMUM OPERATING PRESSURE15.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.03
VOLTAGE STANDING WAVE RATIO1.04
FSC APPLICATION DATAANTENNAS,WAVEGUIDES AND RELATED EQUIP.