5985-01-093-6019 WAVEGUIDE ASSEMBLY Index 5985-01-093-6021 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-01-093-6020

Federal Supply Class:
5985

National Item Identification Number:
010936020

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
05597134228L3 TECHNOLOGIES, INC.
06004834228L3 TECHNOLOGIES, INC.
TR41500806351MICROWAVE ENGINEERING CORPORATION
933D05597134228L3 TECHNOLOGIES, INC.
999D06004834228L3 TECHNOLOGIES, INC.


Techincal Specification:
BEND ANGLE IN DEG90.0 FIRST BEND H-PLANE90.0 FIRST BEND H-PLANE
BEND ANGLE IN DEG90.0 THIRD BEND E-PLANE90.0 THIRD BEND E-PLANE
BEND ANGLE IN DEG90.0 SECOND BEND E-PLANE90.0 SECOND BEND E-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULARINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE DEPTH0.182 INCHES MINIMUM AND 0.182 INCHES MINIMUM AND 0.192 INCHES MAXIMUM SECOND FLANGE0.192 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.195 INCHES MINIMUM AND 0.195 INCHES MINIMUM AND 0.225 INCHES MAXIMUM FIRST FLANGE0.225 INCHES MAXIMUM FIRST FLANGE
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE(S) FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE(S) SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING HOLE DIAMETER0.116 INCHES MINIMUM AND 0.116 INCHES MINIMUM AND 0.118 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES0.118 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
FLANGE INSIDE WIDTH0.279 INCHES MINIMUM AND 0.279 INCHES MINIMUM AND 0.282 INCHES MAXIMUM FIRST FLANGE0.282 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE WIDTH0.362 INCHES MINIMUM AND 0.362 INCHES MINIMUM AND 0.364 INCHES MAXIMUM SECOND FLANGE0.364 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE DIAMETER0.485 INCHES MINIMUM AND 0.485 INCHES MINIMUM AND 0.515 INCHES MAXIMUM FIRST FLANGE0.515 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.139 INCHES MINIMUM AND 0.139 INCHES MINIMUM AND 0.141 INCHES MAXIMUM FIRST FLANGE0.141 INCHES MAXIMUM FIRST FLANGE
FLANGE INSIDE HEIGHT0.222 INCHES MINIMUM AND 0.222 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SECOND FLANGE0.224 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT0.745 INCHES MINIMUM AND 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM SECOND FLANGE0.755 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT0.735 INCHES MINIMUM AND 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM FIRST FLANGE0.765 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH0.735 INCHES MINIMUM AND 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM FIRST FLANGE0.765 INCHES MAXIMUM FIRST FLANGE
FLANGE OUTSIDE WIDTH0.745 INCHES MINIMUM AND 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM SECOND FLANGE0.755 INCHES MAXIMUM SECOND FLANGE
FLANGE QUANTITY22
FLANGE STYLECHOKE TYPE FIRST FLANGE
FLANGE STYLECOVER TYPE SECOND FLANGE
FLEXIBILITYRIGID ALL TUBING SEGMENT
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
INSERTION LOSS IN DECIBELS0.800.80
MATERIALCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
NOMINAL THREAD SIZE0.112 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
VOLTAGE STANDING WAVE RATIO1.301.30
WAVEGUIDE FIRST LEG LENGTH1.500 INCHES NOMINAL
WAVEGUIDE FOURTH LEG LENGTH0.750 INCHES NOMINAL
WAVEGUIDE INSIDE HEIGHT0.139 INCHES MINIMUM AND 0.142 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH0.358 INCHES MINIMUM AND 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM0.362 INCHES MAXIMUM
WAVEGUIDE SECOND LEG LENGTH1.510 INCHES MINIMUM AND 1.550 INCHES MAXIMUM
WAVEGUIDE THIRD LEG LENGTH1.485 INCHES MINIMUM AND 1.515 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.279 INCHES MINIMUM AND 0.282 INCHES MAXIMUM
STYLE DESIGNATORTHREE BEND TYPE
SURFACE TREATMENTPAINT AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
THREAD CLASS2B FIRST FLANGE ALL CONNECTION FACILITIES2B FIRST FLANGE ALL CONNECTION FACILITIES
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIESRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) FIRST FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENTSEAMLESS ALL TUBING SEGMENT