| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE QUANTITY | 2 |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| MATERIAL | ALUMINUM ALLOY 5052 ALL TUBING SEGMENT AND FLANGE |
| MAXIMUM OPERATING PRESSURE | 12.0 POUNDS PER SQUARE INCH GAGE |
| III STYLE DESIGNATOR | BEND TYPE |
| PROPRIETARY CHARACTERISTICS | PACS |
| WAVEGUIDE INSIDE HEIGHT | 0.867 INCHES MINIMUM AND 0.877 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.867 INCHES MINIMUM AND 1.877 INCHES MAXIMUM |
| WAVEGUIDE OFFSET DISTANCE | 3.985 INCHES MINIMUM AND 4.015 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM |
| WAVEGUIDE LONGER OFFSET DISTANCE | 5.305 INCHES MINIMUM AND 5.335 INCHES MAXIMUM |
| SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |