5985-01-029-1641 WAVEGUIDE ASSEMBLY Index 1355-01-029-1643 CATCH

National Stock Number:
5985-01-029-1642

Federal Supply Class:
5985

National Item Identification Number:
010291642

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
100056525154DATA-DESIGN LABORATORIES CORP


Techincal Specification:
STYLE DESIGNATORBEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS ALL TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY2 UNTHREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY
8 UNTHREADED HOLE ALL FLANGES SECOND CONNECTION FACILITY
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID ALL TUBING SEGMENT
MATERIALALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE
WAVEGUIDE LONGER OFFSET DISTANCE13.990 INCHES MINIMUM AND
14.010 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE10.085 INCHES MINIMUM AND
10.105 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.246 INCHES MINIMUM AND
1.254 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND
1.126 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND
0.501 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.621 INCHES MINIMUM AND
0.629 INCHES MAXIMUM
SURFACE TREATMENTCHROMATE AND
CHROMATE ZINC AND
ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND
1.126 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND
0.501 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH2.480 INCHES MINIMUM AND
2.520 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.730 INCHES MINIMUM AND
1.770 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.480 INCHES MINIMUM AND
0.520 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.255 INCHES MINIMUM AND
0.259 INCHES MAXIMUM ALL FLANGES FIRST CONNECTION FACILITY
0.169 INCHES MINIMUM ALL FLANGES SECOND CONNECTION FACILITY
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT