| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.298 INCHES MINIMUM AND 0.328 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM AND 0.147 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 0.705 INCHES MINIMUM AND 0.707 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.394 INCHES MINIMUM AND 0.396 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.298 INCHES MINIMUM AND 1.328 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.298 INCHES MINIMUM AND 1.328 INCHES MAXIMUM ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | COVER TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| INSERTION LOSS IN DECIBELS | 2.50 |
| MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT |
| MATERIAL | COPPER ALLOY ALL FLANGE |
| SPECIAL FEATURES | INCLUDES THREE STRAPS EACH W/HOLE 10-32 UNF-2B |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.15 |
| WAVEGUIDE INSIDE HEIGHT | 0.309 INCHES MINIMUM AND 0.314 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.620 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM |
| SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |