5970-00-565-1210 INSULATION SLEEVING KIT,ELECTRICAL Index 5985-00-565-1270 WAVEGUIDE ASSEMBLY

National Stock Number:
5985-00-565-1229

Federal Supply Class:
5985

National Item Identification Number:
005651229

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
283602410001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY8 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
MATERIALALUMINUM ALLOY SINGLE TUBING SEGMENT
ALUMINUM ALLOY ALL FLANGE
WAVEGUIDE OUTSIDE WIDTH1.000 INCHES NOMINAL
WAVEGUIDE INSIDE WIDTH0.900 INCHES NOMINAL
WAVEGUIDE INSIDE HEIGHT0.400 INCHES NOMINAL
WAVEGUIDE OUTSIDE HEIGHT0.500 INCHES NOMINAL
BEND ANGLE IN DEG23.3 FIRST BEND H-PLANE
90.0 SECOND BEND E-PLANE
90.0 THIRD BEND E-PLANE
SURFACE TREATMENTOXIDE FILM ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH0.897 INCHES MINIMUM AND
0.903 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.397 INCHES MINIMUM AND
0.401 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH2.070 INCHES MINIMUM AND
2.110 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.570 INCHES MINIMUM AND
1.610 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.480 INCHES MINIMUM AND
0.520 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.167 INCHES MINIMUM AND
0.171 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.05
VOLTAGE STANDING WAVE RATIO1.10
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
THE MANUFACTURERS DATA
MANUFACTURERS CODE10001
DESIGN CONTROL REFERENCE2836024