1650-00-562-0219 HOSE ASSEMBLY,RH Index 1560-00-562-0225 RUDDER,AIRCRAFT

National Stock Number:
5985-00-562-0223

Federal Supply Class:
5985

National Item Identification Number:
005620223

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
253667010001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY
4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY
FLANGE STYLECHOKE TYPE FIRST FLANGE
COVER TYPE SECOND FLANGE
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
MATERIALALUMINUM ALLOY SINGLE TUBING SEGMENT
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND
1.004 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND
0.904 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND
0.404 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND
0.504 INCHES MAXIMUM
BEND ANGLE IN DEG90.0 FIRST BEND H-PLANE
90.0 SECOND BEND E-PLANE
SURFACE TREATMENTALUMINUM ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
OXIDE FILM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH0.897 INCHES MINIMUM AND
0.903 INCHES MAXIMUM FIRST FLANGE
1.003 INCHES MINIMUM AND
1.006 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE HEIGHT0.397 INCHES MINIMUM AND
0.403 INCHES MAXIMUM FIRST FLANGE
0.503 INCHES MINIMUM AND
0.506 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM FIRST FLANGE
1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM FIRST FLANGE
1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM SECOND FLANGE
FLANGE INSIDE DIAMETER1.406 INCHES MINIMUM AND
1.437 INCHES MAXIMUM FIRST FLANGE
FLANGE DEPTH0.423 INCHES MINIMUM AND
0.453 INCHES MAXIMUM FIRST FLANGE
0.422 INCHES MINIMUM AND
0.453 INCHES MAXIMUM SECOND FLANGE
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES NOMINAL SECOND FLANGE SINGLE CONNECTION FACILITY
THREAD SERIES DESIGNATORUNC FIRST FLANGE SINGLE CONNECTION FACILITY
NOMINAL THREAD SIZE0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY
THREAD CLASS2B FIRST FLANGE SINGLE CONNECTION FACILITY
THREAD DIRECTIONRIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.10
VOLTAGE STANDING WAVE RATIO1.04
SPECIAL FEATURESMTG. BRACKET WITH ONE PANEL FASTEWER ASSEMBLY ATTACHED,LOCATED ON SHORT LEG 1.475 IN. FROM CENTER OF FASTENER TO FACE OF FLANGE,TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
THE MANUFACTURERS DATA
MANUFACTURERS CODE10001
DESIGN CONTROL REFERENCE2536670