| STYLE DESIGNATOR | WAVEGUIDE TO WAVEGUIDE |
| ADAPTER LENGTH | 1.540 INCHES NOMINAL |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND |
| 1.254 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND |
| 1.126 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND |
| 0.501 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND |
| 0.629 INCHES MAXIMUM |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
| COVER TYPE SECOND FLANGE |
| FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM AND |
| 1.126 INCHES MAXIMUM FIRST FLANGE |
| 1.253 INCHES MINIMUM SECOND FLANGE |
| FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND |
| 0.501 INCHES MAXIMUM FIRST FLANGE |
| 0.628 INCHES MINIMUM SECOND FLANGE |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND |
| 1.890 INCHES MAXIMUM FIRST FLANGE |
| 1.860 INCHES MINIMUM AND |
| 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND |
| 1.890 INCHES MAXIMUM FIRST FLANGE |
| 1.860 INCHES MINIMUM AND |
| 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE DIAMETER | 1.610 INCHES MINIMUM AND |
| 1.640 INCHES MAXIMUM FIRST FLANGE |
| FLANGE DEPTH | 0.610 INCHES MINIMUM AND |
| 0.640 INCHES MAXIMUM FIRST FLANGE |
| 0.423 INCHES MINIMUM AND |
| 0.453 INCHES MAXIMUM SECOND FLANGE |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| THREAD SERIES DESIGNATOR | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
| NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD QUANTITY PER INCH | 32 FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| MAXIMUM OPERATING PRESSURE | 25.0 POUNDS PER SQUARE INCH GAGE |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |