| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE(S) FIRST FLANGE ALL CONNECTION FACILITIES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE(S) SECOND FLANGE ALL CONNECTION FACILITIES |
| FLANGE INSIDE DIAMETER | 1.406 INCHES MINIMUM AND 1.437 INCHES MAXIMUM FIRST FLANGE |
| FLANGE INSIDE DIAMETER | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM FIRST FLANGE |
| FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM FIRST FLANGE |
| FLANGE DEPTH | 0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE |
| FLANGE DEPTH | 0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM SECOND FLANGE |
| FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE |
| FLANGE OUTSIDE WIDTH | 1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLANGE QUANTITY | 3 |
| FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
| FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
| FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM AND 1.640 INCHES MAXIMUM FIRST FLANGE |
| FLEXIBILITY | RIGID ALL TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
| SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
| THREAD CLASS | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD CLASS | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
| THREAD DIRECTION | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD DIRECTION | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) FIRST FLANGE ALL CONNECTION FACILITIES |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) SECOND FLANGE ALL CONNECTION FACILITIES |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
| WAVEGUIDE INSIDE HEIGHT | 0.400 INCHES MINIMUM AND 0.497 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.900 INCHES MINIMUM AND 1.122 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.500 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.000 INCHES MINIMUM AND 1.250 INCHES MAXIMUM |