| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE(S) ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE CONNECTING HOLE DIAMETER | 0.168 INCHES MINIMUM AND 0.171 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.730 INCHES MINIMUM AND 1.770 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 2.480 INCHES MINIMUM AND 2.520 INCHES MAXIMUM ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CONTACT TYPE ALL FLANGES |
| FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| OPERATING PRESSURE | 10.0 POUNDS PER SQUARE INCH GAUGE (PSIG) MAXIMUM |
| MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT AND FLANGE |
| SPECIAL FEATURES | F1NS PROVIDED FOR COOLING; DIMENSIONS 2.250 IN. LG BY 2.187 IN. W BY 0.040 IN. THK; TEMPERATURE RANGE MINUS 28 TO PLUS 65 DEG C |
| TUBING WALL CONSTRUCTION STYLE | CORRUGATED SINGLE TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.08 |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| WAVEGUIDE LENGTH | 9.812 INCHES NOMINAL |
| STYLE DESIGNATOR | STRAIGHT TYPE |
| SURFACE TREATMENT | COPPER SINGLE TUBING SEGMENT INSIDE SURFACES |
| SURFACE TREATMENT | OXIDE SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |