| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE DEPTH | 0.438 INCHES NOMINAL ALL FLANGES |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE(S) ALL FLANGES SINGLE CONNECTION FACILITY |
| FLANGE INSIDE WIDTH | 0.900 INCHES NOMINAL ALL FLANGES |
| FLANGE INSIDE DIAMETER | 1.220 INCHES NOMINAL ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.625 INCHES NOMINAL ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.625 INCHES NOMINAL ALL FLANGES |
| FLANGE QUANTITY | 2 |
| FLANGE STYLE | CHOKE TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| MATERIAL | ALUMINUM SINGLE TUBING SEGMENT |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 10.530 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE HEIGHT | 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE WIDTH | 0.997 INCHES MINIMUM AND 1.003 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
| WAVEGUIDE LENGTH | 8.470 INCHES NOMINAL |
| STYLE DESIGNATOR | OFFSET BEND TYPE |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |