5935-00-165-3472 CONNECTOR,PLUG,ELECTRICAL Index 5935-00-165-3476 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5985-00-165-3473

Federal Supply Class:
5985

National Item Identification Number:
001653473

Description:
SWITCH,RADIO FREQUENCY TRANSMISS

Detail:
An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).


Manufacturer Information:
1054706424ALLIANT TECHSYSTEMS OPERATIONS LLC
230524-00181413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
33102A1LQK8KEYSIGHT TECHNOLOGIES, INC.
33102A28480HEWLETT-PACKARD COMPANY
33102A7ZXR5KEYSIGHT TECHNOLOGIES INC
33102A98734HEWLETT-PACKARD CO MFG DIV
CS118650501EMBERGUARD SOLUTIONS


Techincal Specification:
ACTUATOR CURRENT TYPE AND RATING IN AMPS0.2 DC NOMINAL
ACTUATOR VOLTAGE IN VOLTS-1.0 MINIMUM AND 100.0 MAXIMUM
ACTUATOR OPERATING METHODRELAY
BODY STYLERECTANGULAR
COAXIAL CONNECTOR SERIES DESIGNATIONSMA
CONNECTOR END DESIGNMALE
COUPLING POSITION QUANTITY2
FREQUENCY RATING0.1 GIGAHERTZ MINIMUM AND 1.0 GIGAHERTZ MAXIMUM FIRST FREQUENCY OPERATING
FREQUENCY RATING12.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM SIXTH FREQUENCY OPERATING
FREQUENCY RATING2.0 GIGAHERTZ MINIMUM AND 4.0 GIGAHERTZ MAXIMUM THIRD FREQUENCY OPERATING
FREQUENCY RATING1.0 GIGAHERTZ MINIMUM AND 2.0 GIGAHERTZ MAXIMUM SECOND FREQUENCY OPERATING
FREQUENCY RATING4.0 GIGAHERTZ MINIMUM AND 8.0 GIGAHERTZ MAXIMUM FOURTH FREQUENCY OPERATING
FREQUENCY RATING8.0 GIGAHERTZ MINIMUM AND 12.4 GIGAHERTZ MAXIMUM FIFTH FREQUENCY OPERATING
INSERTION LOSS IN DECIBELS1.00 FIRST
INSERTION LOSS IN DECIBELS1.00 SECOND
INSERTION LOSS IN DECIBELS1.30 THIRD
INSERTION LOSS IN DECIBELS2.00 FIFTH
INSERTION LOSS IN DECIBELS2.00 FOURTH
INSERTION LOSS IN DECIBELS2.50 SIXTH
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS0.480 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS0.480 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN
OPERATING TEMP RANGE-55.0 TO 71.0 CELSIUS
OVERALL HEIGHT0.420 INCHES NOMINAL
OVERALL LENGTH2.000 INCHES NOMINAL
OVERALL WIDTH0.975 INCHES NOMINAL
MATERIALMETAL BODY
MINIMUM CROSSTALK RATING IN DECIBELS45.0 FOURTH
MINIMUM CROSSTALK RATING IN DECIBELS45.0 SIXTH
MINIMUM CROSSTALK RATING IN DECIBELS33.0 FIRST
MINIMUM CROSSTALK RATING IN DECIBELS35.0 SECOND
MINIMUM CROSSTALK RATING IN DECIBELS40.0 THIRD
MINIMUM CROSSTALK RATING IN DECIBELS45.0 FIFTH
MOUNTING FACILITY PATTERNTWO POSITION DIAGONAL SINGLE MOUNTING FACILITY PATTERN
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE(S)
POLE QUANTITY1
RF POWER HANDLING CAPABILITY2.0 WATTS AVERAGE FIRST
RF POWER HANDLING CAPABILITY75.0 WATTS PEAK SECOND
SPECIAL FEATURESSHOCK,MOISTURE AND CORROSION RESISTANT PER MIL-STD-883
UNTHREADED MOUNTING HOLE DIAMETER0.125 INCHES NOMINAL
VOLTAGE STANDING WAVE RATIO1.80 THIRD
VOLTAGE STANDING WAVE RATIO1.70 FIRST
VOLTAGE STANDING WAVE RATIO1.70 SECOND
VOLTAGE STANDING WAVE RATIO2.00 FOURTH
VOLTAGE STANDING WAVE RATIO2.00 FIFTH
VOLTAGE STANDING WAVE RATIO2.50 SIXTH
SWITCHING TIME50.0 NANOSECONDS
SWITCH OPERATION SEQUENCEMAKES BEFORE BREAKS
SWITCH RETURN MECHANISM TYPEFAIL-SAFE
SWITCH TYPENONTRANSFER
TERMINAL TYPE AND QUANTITY3 RECEPTACLE, COAXIAL
THROW QUANTITY1


Click here to Register for Free 30-day Trial