| WAVEGUIDE INSIDE HEIGHT | 0.168 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
| FLANGE DEPTH | 0.123 INCHES MINIMUM FIRST FLANGE AND 0.153 INCHES MAXIMUM FIRST FLANGE |
| FLANGE QUANTITY | 2 |
| WAVEGUIDE INSIDE WIDTH | 0.417 INCHES MINIMUM AND 0.423 INCHES MAXIMUM |
| WAVEGUIDE LENGTH | 3.596 INCHES NOMINAL |
| FLANGE OUTSIDE WIDTH | 0.860 INCHES MINIMUM FIRST FLANGE AND 0.890 INCHES MAXIMUM FIRST FLANGE |
| FLANGE STYLE | COVER TYPE FIRST FLANGE |
| FLEXIBILITY | RIGID ALL TUBING SEGMENT |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS ALL TUBING SEGMENT |
| VOLTAGE STANDING WAVE RATIO | 1.08 |
| WAVEGUIDE OUTSIDE HEIGHT | 0.247 INCHES MINIMUM AND 0.253 INCHES MAXIMUM |
| FLANGE INSIDE HEIGHT | 0.253 INCHES MINIMUM FIRST FLANGE AND 0.255 INCHES MAXIMUM FIRST FLANGE |
| SURFACE TREATMENT | ANY ACCEPTABLE FIRST TUBING SEGMENT AND FLANGE ALL SURFACES |
| WAVEGUIDE CENTER TO CENTER DISTANCE | 0.715 INCHES MINIMUM AND 0.735 INCHES MAXIMUM |
| FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| MATERIAL | ALUMINUM ALLOY FIRST TUBING SEGMENT AND FLANGE |
| FLANGE OUTSIDE HEIGHT | 0.860 INCHES MINIMUM FIRST FLANGE AND 0.890 INCHES MAXIMUM FIRST FLANGE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.118 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
| WAVEGUIDE OUTSIDE WIDTH | 0.497 INCHES MINIMUM AND 0.503 INCHES MAXIMUM |
| FLANGE INSIDE WIDTH | 0.503 INCHES MINIMUM FIRST FLANGE AND 0.505 INCHES MAXIMUM FIRST FLANGE |
| STYLE DESIGNATOR | OFFSET BEND TYPE |