4920-01-432-1076 FIXTURE,FUEL SYSTEM COMPONENTS,A Index 7690-01-432-1078 MARKER,IDENTIFICATION

National Stock Number:
5970-01-432-1077

Federal Supply Class:
5970

National Item Identification Number:
014321077

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A023-4/18006090TE CONNECTIVITY CORPORATION
A320547880063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.980 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.690 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH3.670 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC POLYOLEFIN
COLORBLACK
FLEXIBILITYFLEXIBLE
TEMP RATING-55.0 DEG CELSIUS AND
135.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS225.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND
FLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT AND
WATER RESISTANT
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESINSIDE ADHESIVE COATED
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
MAIN BODY INSIDE DIAMETER1.000 INCHES MINIMUM AS SUPPLIED
0.520 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED
0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.460 INCHES MINIMUM AS SUPPLIED


Click here to Register for Free 30-day Trial