4140-01-381-6729 FAN,VANEAXIAL Index 6150-01-381-6731 LEAD,ELECTRICAL

National Stock Number:
5970-01-381-6730

Federal Supply Class:
5970

National Item Identification Number:
013816730

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
1241456119207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
12414561-001076M6AMZ ALABAMA INC.
12414561-0010FW39BAE SYSTEMS TACTICAL VEHICLE SYSTEMS LP
12414561-00119207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
493H123-6-250209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
493H123-6-250533873M COMPANY
493H123-6-25075037MINNESOTA MINING AND MFG CO 3M COMPANY
493H123-6-250763813M COMPANY


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES22.4 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH19.3 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT
FIRST BRANCH INSIDE DIAMETER3.3 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER6.6 MILLIMETERS MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS1.02 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER13.2 MILLIMETERS MINIMUM AS SUPPLIED
MAIN BODY INSIDE DIAMETER6.1 MILLIMETERS MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS1.52 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONMIL-I-81765/1, TYPE 2 MIL SPEC SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC CROSS-LINKED POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
SPECIAL FEATURESADHESIVE COATING
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER1.02 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS1.02 MILLIMETERS MINIMUM AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS


Click here to Register for Free 30-day Trial