5999-01-333-6610 CONTACT,ELECTRICAL Index 6230-01-333-6612 LIGHT SET,MARKER,GROUND OBSTRUCT

National Stock Number:
5970-01-333-6611

Federal Supply Class:
5970

National Item Identification Number:
013336611

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
381A115-3/4206090TE CONNECTIVITY CORPORATION
GS830AD1-3A26512NORTHROP GRUMMAN SYSTEMS CORPORATION


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES3.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH3.320 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
FIRST BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYSEMIRIGID
MAIN BODY WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.120 INCHES MINIMUM AS SUPPLIED
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED
MATERIALPLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER1.060 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESINTERNAL ADHESIVE COATING
STYLE DESIGNATORTRANSITION-Y
TEMP RATING-55.0 CELSIUS AND 135.0 CELSIUS


Click here to Register for Free 30-day Trial