| STYLE DESIGNATOR | TRANSITION-Y |
| MAIN BODY INSIDE DIAMETER | 1.350 INCHES MINIMUM AS SUPPLIED |
| 0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH INSIDE DIAMETER | 0.900 INCHES MINIMUM AS SUPPLIED |
| 0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH INSIDE DIAMETER | 0.900 INCHES MINIMUM AS SUPPLIED |
| 0.450 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 2.480 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MAIN BODY WALL THICKNESS | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH WALL THICKNESS | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH WALL THICKNESS | 0.050 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 2.480 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATERIAL | PLASTIC,ELASTOMERIC POLYMER BLEND,RT-1321,RAYCHEM CORP |
| COLOR | BLACK |
| FLEXIBILITY | FLEXIBLE |
| TEMP RATING | -55.0 DEG CELSIUS |
| MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
| DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
| ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND |
| MILDEW RESISTANT |
| SPECIFICATION/STANDARD DATA | 96906-MIL-STD100 GOVERNMENT STANDARD AND |
| 80204-ANSI Y14.5M-1982 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 19207 |
| MFR SOURCE CONTROLLING REFERENCE | 12273148 (SOURCE CONTROL) |