Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
12307569-219207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM


Techincal Specification:
STYLE DESIGNATORTRANSITION-Y
MAIN BODY INSIDE DIAMETER0.820 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.820 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.820 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.620 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.050 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.050 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.050 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES2.480 INCHES MINIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG45.0 MINIMUM AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC,ELASTOMERIC POLYMER BLEND,RT-1321,RAYCHEM CORP
COLORBLACK
FLEXIBILITYFLEXIBLE
TEMP RATING248.0 DEG FAHRENHEIT
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONFLAME RESISTANT
RELIABILITY INDICATORNOT ESTABLISHED
THE MANUFACTURERS DATA