5970-00-998-2216 INSULATION SLEEVING,ELECTRICAL,S Index 5970-00-998-2219 INSULATION SLEEVING,ELECTRICAL,S

National Stock Number:
5970-00-998-2217

Federal Supply Class:
5970

National Item Identification Number:
009982217

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
202-25204-180378TRIUMPH AEROSTRUCTURES, LLC
462A011-506090TE CONNECTIVITY CORPORATION
C1507-1-581755LOCKHEED MARTIN CORPORATION


Techincal Specification:
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
0.260 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.820 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH1.820 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER,NEOPRENE,RT-501,RAYCHEM CORP
COLORBLACK
FLEXIBILITYFLEXIBLE
TEMP RATING-55.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONFLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT AND
WATER RESISTANT


Click here to Register for Free 30-day Trial