5970-00-939-8489 INSULATION SLEEVING,ELECTRICAL,S Index 4730-00-939-8492 CAP,TUBE

National Stock Number:
5970-00-939-8490

Federal Supply Class:
5970

National Item Identification Number:
009398490

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
411-1-B7K0720HELLERMANNTYTON LTD
411-1-B7K1793HELLERMANNTYTON LIMITED
562A022-306090TE CONNECTIVITY CORPORATION
562A022-3-006090TE CONNECTIVITY CORPORATION
67311133209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
6731113375037MINNESOTA MINING AND MFG CO 3M COMPANY
673H133-1209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
673111337V059MINNESOTA MINING AND MFG CO


Techincal Specification:
STYLE DESIGNATORTRANSITION-1 TO 4 CABLES
MAIN BODY INSIDE DIAMETER0.760 INCHES MINIMUM AS SUPPLIED
0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.370 INCHES MINIMUM AS SUPPLIED
0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.370 INCHES MINIMUM AS SUPPLIED
0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.370 INCHES MINIMUM AS SUPPLIED
0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER0.370 INCHES MINIMUM AS SUPPLIED
0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH1.400 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH1.260 INCHES NOMINAL AS SUPPLIED
MAIN BODY WALL THICKNESS0.070 INCHES MAXIMUM AS SUPPLIED
0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.040 INCHES MAXIMUM AS SUPPLIED
0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.040 INCHES MAXIMUM AS SUPPLIED
0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS0.040 INCHES MAXIMUM AS SUPPLIED
0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH WALL THICKNESS0.040 INCHES MAXIMUM AS SUPPLIED
0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES1.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
15.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP
COLORBLACK
FLEXIBILITYSEMIRIGID
TEMP RATING-55.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND
FLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT AND
WATER RESISTANT
RELIABILITY INDICATORNOT ESTABLISHED