5935-00-879-7316 SOCKET,PLUG-IN ELECTRONIC COMPON Index 5905-00-879-7318 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5970-00-879-7317

Federal Supply Class:
5970

National Item Identification Number:
008797317

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
202-25204-380378TRIUMPH AEROSTRUCTURES, LLC
462A034-506090TE CONNECTIVITY CORPORATION
5734145-234011CONTROL DATA SYSTEMS INC ENGINEERING SERVICES DIV


Techincal Specification:
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES2.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH2.900 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG30.0 NOMINAL AFTER UNRESTRICTED RECOVERY
COLORBLACK
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS200.0
FIRST BRANCH INSIDE DIAMETER0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.760 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY INSIDE DIAMETER0.740 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER1.520 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH5.320 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALRUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED
MINIMUM TENSILE STRENGTH1500 POUNDS PER SQUARE INCH
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.760 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
TEMP RATING-55.0 CELSIUS AND 150.0 CELSIUS
THIRD BRANCH INSIDE DIAMETER0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.760 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY