| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.510 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 0.950 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 0.950 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| COLOR | BLACK |
| DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 200.0 |
| ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
| FIRST BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH INSIDE DIAMETER | 0.260 INCHES MINIMUM AS SUPPLIED |
| FIRST BRANCH WALL THICKNESS | 0.040 INCHES MAXIMUM AS SUPPLIED |
| FIRST BRANCH WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FLEXIBILITY | SEMIRIGID |
| FOURTH BRANCH INSIDE DIAMETER | 0.260 INCHES MINIMUM AS SUPPLIED |
| FOURTH BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FOURTH BRANCH WALL THICKNESS | 0.040 INCHES MAXIMUM AS SUPPLIED |
| FOURTH BRANCH WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MAIN BODY INSIDE DIAMETER | 0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| MAIN BODY INSIDE DIAMETER | 0.520 INCHES MINIMUM AS SUPPLIED |
| MAIN BODY WALL THICKNESS | 0.060 INCHES MAXIMUM AS SUPPLIED |
| MAIN BODY WALL THICKNESS | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATERIAL DOCUMENT AND CLASSIFICATION | RT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE LOCATION NOT OTHERWISE SPECIFIED |
| MATERIAL | PLASTIC POLYOLEFIN LOCATION NOT OTHERWISE SPECIFIED |
| MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SECOND BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH INSIDE DIAMETER | 0.260 INCHES MINIMUM AS SUPPLIED |
| SECOND BRANCH WALL THICKNESS | 0.040 INCHES MAXIMUM AS SUPPLIED |
| SECOND BRANCH WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
| TEMP RATING | -55.0 CELSIUS AND 225.0 CELSIUS |
| THIRD BRANCH INSIDE DIAMETER | 0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH INSIDE DIAMETER | 0.260 INCHES MINIMUM AS SUPPLIED |
| THIRD BRANCH WALL THICKNESS | 0.040 INCHES MAXIMUM AS SUPPLIED |
| THIRD BRANCH WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |