| STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
| MAIN BODY INSIDE DIAMETER | 1.520 INCHES MINIMUM AS SUPPLIED |
| 0.730 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
| 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
| 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
| 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| FOURTH BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
| 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 2.830 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 2.570 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| MAIN BODY WALL THICKNESS | 0.120 INCHES MAXIMUM AS SUPPLIED |
| 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FIRST BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
| 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| SECOND BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
| 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| THIRD BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
| 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| FOURTH BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
| 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 2.950 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
| MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
| COLOR | BLACK |
| FLEXIBILITY | SEMIRIGID |
| TEMP RATING | -55.0 DEG CELSIUS |
| MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
| DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
| ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND |
| FLAME RESISTANT AND |
| MILDEW RESISTANT AND |
| SOLVENT RESISTANT AND |
| WATER RESISTANT |
| RELIABILITY INDICATOR | NOT ESTABLISHED |