5970-00-102-1495 INSULATION SLEEVING,ELECTRICAL Index 1560-00-102-1497 FITTING,UPLOCK

National Stock Number:
5970-00-102-1496

Federal Supply Class:
5970

National Item Identification Number:
001021496

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
11447846-218876U S ARMY AVIATION AND MISSILE COMMAND
1166315719207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
13238521-118876U S ARMY AVIATION AND MISSILE COMMAND
11663157-119207U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-IM-MM
202-25212-580378TRIUMPH AEROSTRUCTURES, LLC
206-1-JK0720HELLERMANNTYTON LTD
382A012-406090TE CONNECTIVITY CORPORATION
382A12-4-006090TE CONNECTIVITY CORPORATION
493H123-6209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
382A012-4F0286TYCO ELECTRONICS FRANCE SAS
382A012-4F6220RAYCHEM SA
206-1-JK1793HELLERMANNTYTON LIMITED


Techincal Specification:
STYLE DESIGNATORTRANSITION-Y
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.130 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.760 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.880 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG10.0 NOMINAL AS SUPPLIED
22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC,POLYOLEFIN,RT-1304,RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPF-666,HIGH VOLTAGE ENGINEERING CORP
COLORBLACK
FLEXIBILITYFLEXIBLE
TEMP RATING-55.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND
FLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT AND
WATER RESISTANT
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESADHESIVE COATING