5970-00-025-9126 INSULATION SLEEVING,ELECTRICAL,S Index 2930-00-025-9128 HOUSING,BLOWER

National Stock Number:
5970-00-025-9127

Federal Supply Class:
5970

National Item Identification Number:
000259127

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
13238519-118876U S ARMY AVIATION AND MISSILE COMMAND
200AS307-130003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
342A012-406090TE CONNECTIVITY CORPORATION
453H123-6209993M CO ADMININISTRATIVE ELECTRONIC & COMMUNICATIONS
453H123-6533873M COMPANY
202-25211-680378TRIUMPH AEROSTRUCTURES, LLC
453H123-675037MINNESOTA MINING AND MFG CO 3M COMPANY
453H123-67V059MINNESOTA MINING AND MFG CO


Techincal Specification:
STYLE DESIGNATORTRANSITION-45 DEGREES
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
0.270 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.920 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES0.900 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY OVERALL LENGTH1.940 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIALPLASTIC,POLYOLEFIN,RT-1304,RAYCHEM CORP
COLORBLACK
FLEXIBILITYFLEXIBLE
TEMP RATING-55.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH1200 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND
FLAME RESISTANT AND
MILDEW RESISTANT AND
SOLVENT RESISTANT AND
WATER RESISTANT
RELIABILITY INDICATORNOT ESTABLISHED