5955-00-251-2989 CRYSTAL UNIT,QUARTZ Index 5955-00-251-2993 CRYSTAL UNIT,QUARTZ

National Stock Number:
5955-00-251-2991

Federal Supply Class:
5955

National Item Identification Number:
002512991

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
4016181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
40161-5722-22KC81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-1683681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC1683681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH0.570 INCHES NOMINAL
BODY THICKNESS0.315 INCHES NOMINAL
BODY WIDTH0.720 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.486 INCHES NOMINAL
CIRCUIT RESONANCEANTIRESONANCE
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.007 TO 0.007
OVERALL LENGTH0.800 INCHES MAXIMUM
OVERALL THICKNESS0.343 INCHES MAXIMUM
OVERALL WIDTH0.750 INCHES MAXIMUM
MODE OF OSCILLATIONFUNDAMENTAL
OPERATING TEMP RANGE+50.0 TO 85.0 CELSIUS
SPECIFIED FREQUENCY5.72222 KILOHERTZ
STYLE DESIGNATOROVAL BODY, PIN TERMINALS
TERMINAL LENGTH0.207 INCHES NOMINAL
TERMINAL DIAMETER0.030 INCHES NOMINAL


Click here to Register for Free 30-day Trial