TERMINAL TYPE AND QUANTITY | 6 TURRET |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| 28.00 DC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
WINDING OPERATING CURRENT | 2.14 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
MAXIMUM TRANSFORMER POWER RATING | 120.0 VOLT-AMPERE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 2 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.910 INCHES MINIMUM AND |
| 1.950 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.480 INCHES MINIMUM AND |
| 1.520 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
OVERALL LENGTH | 2.410 INCHES MINIMUM AND |
| 2.450 INCHES MAXIMUM |
OVERALL HEIGHT | 2.320 INCHES MAXIMUM |
OVERALL WIDTH | 2.080 INCHES MINIMUM AND |
| 2.120 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPEC/STD CONTROLLING DATA | |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-27/336 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M27/336-08 |