5905-01-381-9365 RESISTOR,CHIP,FIXED,FILM Index 5905-01-381-9367 RESISTOR,ADJUSTABLE

National Stock Number:
5950-01-381-9366

Federal Supply Class:
5950

National Item Identification Number:
013819366

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
0-1704T209349MAGNETIC CIRCUIT ELEMENTS INC
666838853711NAVAL SEA SYSTEMS COMMAND


Techincal Specification:
BODY HEIGHT0.804 INCHES MINIMUM AND 0.910 INCHES MAXIMUM
BODY LENGTH1.360 INCHES MINIMUM AND 1.400 INCHES MAXIMUM
BODY WIDTH1.020 INCHES NOMINAL
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.095 INCHES MINIMUM AND 1.105 INCHES MAXIMUM SINGLE MOUNTING FACILITY SECOND CENTER GROUP
FREQUENCY RATING62.5 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY1 FIRST GROUP
MOUNTING FACILITY QUANTITY2 SECOND GROUP
MOUNTING HOLE DIAMETER0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM SECOND GROUP
MOUNTING HOLE DIAMETER0.175 INCHES NOMINAL FIRST GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE(S) SECOND GROUP
MOUNTING METHODUNTHREADED HOLE(S) FIRST GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT10.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE7.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY5 TURRET


Click here to Register for Free 30-day Trial