5995-01-380-1270 CABLE ASSEMBLY,SPECIAL PURPOSE,E Index 7320-01-380-1272 DISPENSER,TABLEWARE

National Stock Number:
5950-01-380-1271

Federal Supply Class:
5950

National Item Identification Number:
013801271

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
549582915090RAYTHEON COMPANY
549582953711NAVAL SEA SYSTEMS COMMAND
DGM/M-470VA-60HZ-40071034608D1739COOPER CROUSE-HINDS GMBH STANDORTEBERBACH


Techincal Specification:
BODY LENGTH160.0 MILLIMETERS NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH85.0 MILLIMETERS NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT155.0 MILLIMETERS NOMINAL
OVERALL LENGTH160.0 MILLIMETERS NOMINAL
OVERALL WIDTH100.0 MILLIMETERS NOMINAL
MAXIMUM OPERATING TEMP65.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
MOUNTING SLOT WIDTH7.0 MILLIMETERS NOMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT12.3 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE21.80 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING POWER RATING470.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY2 TERMINAL BLOCK W/SCREWS


Click here to Register for Free 30-day Trial