| TERMINAL TYPE AND QUANTITY | 13 TAB, SOLDER LUG |
| WINDING OPERATING VOLTAGE | 173.00 AC VOLTS MINIMUM AND |
| 216.50 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND MOUNTING SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 3 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.550 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | OPEN |
| OVERALL LENGTH | 3.040 INCHES MAXIMUM |
| OVERALL HEIGHT | 1.520 INCHES MAXIMUM |
| OVERALL WIDTH | 2.160 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEST DATA DOCUMENT | 95105-276-0026 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND |
| DELTA-WYE |
| MAXIMUM OPERATING TEMP | 140.0 DEG CELSIUS |