| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 50.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| INCLOSURE TYPE | OPEN |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| PROPRIETARY CHARACTERISTICS | PACS |
| MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
| MOUNTING METHOD | CLIP SINGLE GROUP |
| OVERALL HEIGHT | 0.700 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 8.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| WINDING OPERATING VOLTAGE | 108.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| WINDING OPERATING VOLTAGE | 18.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 96.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD AND 6 PRINTED CIRCUIT |
| TEST DATA DOCUMENT | 59782-01015103 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |