5950-01-339-8204

Federal Supply Class:
5950

National Item Identification Number:
013398204

Description:
TRANSFORMER ASSEMBLY

Detail:
TWO OR MORE SEPARABLE TRANSFORMER (AS MODIFIED) ON A COMMON MOUNTING OR MOUNTED ON EACH OTHER.


Manufacturer Information:
10132963A486GNIMIKKEISTOKESKUS NCB FINLAND
12020-155196SORA POWER INC.
984882-5B82577RAYTHEON COMPANY
321-18050-0595266OECO, LLC


Techincal Specification:
BODY WIDTH3.440 INCHES MAXIMUM
DC RESISTANCE RATING IN OHMS0.040 THIRD COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS0.060 FIRST COMPONENT SECOND SECONDARY
DC RESISTANCE RATING IN OHMS0.090 SECOND COMPONENT FOURTH SECONDARY
DC RESISTANCE RATING IN OHMS0.100 THIRD COMPONENT FIRST SECONDARY
DC RESISTANCE RATING IN OHMS0.200 FIRST COMPONENT FIRST SECONDARY
DC RESISTANCE RATING IN OHMS0.200 FIRST COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS0.200 FIRST COMPONENT THIRD SECONDARY
DC RESISTANCE RATING IN OHMS0.280 SECOND COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS1.200 SECOND COMPONENT FIRST SECONDARY
DC RESISTANCE RATING IN OHMS12.000 SECOND COMPONENT SECOND SECONDARY
DC RESISTANCE RATING IN OHMS2.750 FIRST COMPONENT FOURTH SECONDARY
DISTANCE BETWEEN MOUNTING FACILITY CENTERS4.500 INCHES NOMINAL FIRST MOUNTING FACILITY SINGLE CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS5.375 INCHES NOMINAL THIRD MOUNTING FACILITY SINGLE CENTER GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS2.500 INCHES NOMINAL SECOND MOUNTING FACILITY SINGLE CENTER GROUP
FEATURES PROVIDEDW/RECTIFIER
FREQUENCY RATING10.0 KILOHERTZ NOMINAL ALL COMPONENTS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE ALL COMPONENTS
OVERALL HEIGHT3.570 INCHES MAXIMUM
OVERALL LENGTH6.030 INCHES MAXIMUM
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY2 FIRST GROUP
MOUNTING FACILITY QUANTITY2 SECOND GROUP
MOUNTING HOLE DIAMETER0.500 INCHES NOMINAL SECOND GROUP
MOUNTING METHODSLOT FIRST GROUP
MOUNTING METHODTAB THIRD GROUP
MOUNTING METHODUNTHREADED HOLE(S) SECOND GROUP
MOUNTING TAB WIDTH0.625 INCHES NOMINAL
MOUNTING SLOT WIDTH0.187 INCHES NOMINAL FIRST GROUP
RATING METHODELECTRICAL ALL COMPONENTS THIRD SECONDARY
RATING METHODELECTRICAL FIRST COMPONENT FOURTH SECONDARY
RATING METHODELECTRICAL ALL COMPONENTS FIRST SECONDARY
RATING METHODELECTRICAL ALL COMPONENTS SECOND SECONDARY
RATING METHODELECTRICAL ALL COMPONENTS SINGLE PRIMARY
RATING METHODELECTRICAL SECOND COMPONENT FOURTH SECONDARY
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY FIRST COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SECOND COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY THIRD COMPONENT
WINDING OPERATING CURRENT0.01 AMPERES AC NOMINAL THIRD COMPONENT FIRST SECONDARY
WINDING OPERATING CURRENT0.035 AMPERES AC NOMINAL THIRD COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT1.2 AMPERES DC NOMINAL THIRD COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT3.0 AMPERES AC NOMINAL SECOND COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC NOMINAL FIRST COMPONENT FOURTH SECONDARY
WINDING OPERATING CURRENT35.0 MILLIAMPERES AC NOMINAL SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC NOMINAL SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING CURRENT50.0 MILLIAMPERES AC NOMINAL SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE106.05 AC VOLTS NOMINAL FIRST COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE130.00 DC VOLTS MINIMUM AND 137.00 DC VOLTS MAXIMUM THIRD COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE14.14 AC VOLTS NOMINAL SECOND COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE149.88 AC VOLTS NOMINAL SECOND COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL FIRST COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE15.55 AC VOLTS NOMINAL THIRD COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE16.26 AC VOLTS NOMINAL THIRD COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE178.16 AC VOLTS NOMINAL AND 195.84 AC VOLTS NOMINAL AND 213.57 AC VOLTS NOMINAL THIRD COMPONENT THIRD SECONDARY
WINDING OPERATING VOLTAGE70.70 AC VOLTS NOMINAL SECOND COMPONENT SECOND SECONDARY
WINDING OPERATING VOLTAGE530.25 AC VOLTS NOMINAL FIRST COMPONENT FOURTH SECONDARY
WINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL SECOND COMPONENT FIRST SECONDARY
WINDING OPERATING VOLTAGE6.01 AC VOLTS NOMINAL SECOND COMPONENT FOURTH SECONDARY
WINDING POWER RATING5245.8 VOLTS-AMPERES SECOND COMPONENT THIRD SECONDARY
WINDING POWER RATING7.47 VOLTS-AMPERES THIRD COMPONENT THIRD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL THIRD COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SECOND COMPONENT
WINDING POWER RATING0.2 VOLTS-AMPERES THIRD COMPONENT FIRST SECONDARY
WINDING POWER RATING159.07 VOLTS-AMPERES FIRST COMPONENT FOURTH SECONDARY
WINDING POWER RATING160.2 VOLTS-AMPERES THIRD COMPONENT SECOND SECONDARY
WINDING POWER RATING18.03 VOLTS-AMPERES SECOND COMPONENT FOURTH SECONDARY
WINDING POWER RATING300.5 VOLTS-AMPERES SECOND COMPONENT FIRST SECONDARY
WINDING POWER RATING3535.0 VOLTS-AMPERES SECOND COMPONENT SECOND SECONDARY
TERMINAL TYPE AND QUANTITY36 WIRE LEAD