5950-01-333-1312 COIL,RADIO FREQUENCY Index 5920-01-333-1314 RETAINER,FUSE

National Stock Number:
5950-01-333-1313

Federal Supply Class:
5950

National Item Identification Number:
013331313

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
WIS-12072-216236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)
WIS-12072-2U2248SELEX ELSAG LTD


Techincal Specification:
TERMINAL TYPE AND QUANTITY21 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE10.00 AC VOLTS NOMINAL AND
400.00 AC VOLTS NOMINAL AND
420.00 AC VOLTS NOMINAL AND
440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
900.00 AC VOLTS NOMINAL AND
940.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT3.84 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING48.5 HERTZ MINIMUM AND
61.5 HERTZ MAXIMUM SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING6.5 KILOVOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY1 PRIMARY AND
1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHODPLUG-IN 1ST GROUP
UNTHREADED HOLE 2ND GROUP
MOUNTING FACILITY QUANTITY2 2ND GROUP
MOUNTING HOLE DIAMETER12.0 MILLIMETERS NOMINAL 2ND GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS13.990 INCHES MINIMUM AND
14.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
OVERALL LENGTH20.812 INCHES MAXIMUM
OVERALL HEIGHT9.250 INCHES MAXIMUM
OVERALL WIDTH15.500 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPEDELTA-WYE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONHUMIDITY RESISTANT


Click here to Register for Free 30-day Trial