TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
WINDING QUANTITY | 2 SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
WINDING CONDUCTOR SIZE | 0.05082 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT ALL WINDING |
WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST WINDING |
| 3.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND WINDING |
DC RESISTANCE RATING IN OHMS | 0.150 SINGLE COMPONENT 1ST WINDING |
| 1.600 SINGLE COMPONENT 2ND WINDING |
INDUCTANCE RATING | 25.00 MICROHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING |
| 500.00 MICROHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING |
FREQUENCY RATING | 1.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
MOUNTING METHOD | TERMINAL SINGLE GROUP |
BODY LENGTH | 3.072 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 3.720 INCHES MAXIMUM |
FEATURES PROVIDED | COLOR CODED TERMINAL |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TEST DATA DOCUMENT | 13973-841366 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
MAXIMUM OPERATING TEMP | 71.0 DEG CELSIUS |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND |
| VIBRATION RESISTANT AND |
| FUNGUS RESISTANT |