5950-01-326-4299 COIL,ELECTRICAL Index 5950-01-326-4301 TRANSFORMER,POWER

National Stock Number:
5950-01-326-4300

Federal Supply Class:
5950

National Item Identification Number:
013264300

Description:
COIL,ELECTRICAL

Detail:
An item generally consisting of one or more turns of wire or similar conductive material (in special cases it may be considered as a partial turn). It is specifically designed to concentrate magnetic flux generated by the flow of an electric current, to induce in itself an electromotive force, and to add or subtract inductive reactance in a circuit. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). For coils wound on resistors which are designed to be inserted into the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC..


Manufacturer Information:
51-151-0108748ELDEC AEROSPACE CORP
TF51-151-0108748ELDEC AEROSPACE CORP


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.650 INCHES NOMINAL FIRST MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.850 INCHES NOMINAL SECOND MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.305 INCHES NOMINAL SECOND MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.100 INCHES NOMINAL FIRST MOUNTING FACILITY SINGLE CENTER GROUP
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS0.040 SINGLE COMPONENT ALL WINDING
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING240.00 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING
OVERALL HEIGHT1.400 INCHES MAXIMUM
OVERALL LENGTH5.230 INCHES MINIMUM AND 5.270 INCHES MAXIMUM
OVERALL WIDTH3.480 INCHES MINIMUM AND 3.520 INCHES MAXIMUM
MAXIMUM OPERATING TEMP67.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SECOND GROUP
MOUNTING FACILITY QUANTITY4 FIRST GROUP
MOUNTING METHODTHREADED HOLE(S) FIRST GROUP
MOUNTING METHODTHREADED STUD(S) SECOND GROUP
NOMINAL THREAD SIZE0.138 INCHES ALL GROUPINGS
RATING METHODELECTRICAL SINGLE COMPONENT ALL WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING VOLTAGE1.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL WINDING
WINDING QUANTITY6 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY12 WIRE LEAD
TEST DATA DOCUMENT08748-TF51-151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS