5950-01-325-7499 COIL,RADIO FREQUENCY Index 5950-01-325-7501 TRANSFORMER,POWER

National Stock Number:
5950-01-325-7500

Federal Supply Class:
5950

National Item Identification Number:
013257500

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
128EDCA00100-126512NORTHROP GRUMMAN SYSTEMS CORPORATION
128EDCA00100-179RG9NORTHROP GRUMMAN SYSTEMS CORPORATION
4339873386FREED TRANSFORMER CO


Techincal Specification:
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS1.350 SINGLE COMPONENT SINGLE WINDING
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.040 INCHES MINIMUM AND 1.100 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING4.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
OVERALL HEIGHT0.860 INCHES MAXIMUM
OVERALL LENGTH1.260 INCHES MINIMUM AND 1.320 INCHES MAXIMUM
OVERALL WIDTH0.890 INCHES MAXIMUM
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED HOLE(S) SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT400.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 PIN
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP