5950-01-325-0432 TRANSFORMER,POWER AUTOTRANSFORME Index 5950-01-325-0434 TRANSFORMER,POWER AUTOTRANSFORME

National Stock Number:
5950-01-325-0433

Federal Supply Class:
5950

National Item Identification Number:
013250433

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
512655P155455LIEBERT CORP
9T23B387103497GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
9T23B387103512GENERAL ELECTRIC CO SPECIALTY TRANSFORMER DEPT
9T23B387160969GENERAL ELECTRIC CO ELECTRICAL DISTRIBUTION AND CONTROL


Techincal Specification:
MOUNTING METHODSLOT SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
OVERALL HEIGHT24.250 INCHES MAXIMUM
OVERALL LENGTH20.560 INCHES MAXIMUM
OVERALL WIDTH19.000 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA OR WYE-WYE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH15.970 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 16.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH14.350 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 14.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.410 INCHES MINIMUM SINGLE GROUP AND 0.478 INCHES MAXIMUM SINGLE GROUP
MOUNTING SLOT WIDTH0.410 INCHES MINIMUM SINGLE GROUP AND 0.478 INCHES MAXIMUM SINGLE GROUP