| BODY WIDTH | 2.500 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.625 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| FREQUENCY RATING | 47.5 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
| INCLOSURE TYPE | FULLY INCLOSED |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| OVERALL HEIGHT | 3.250 INCHES MAXIMUM |
| OVERALL LENGTH | 5.000 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 105.0 CELSIUS |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| MOUNTING METHOD | SLOT SINGLE GROUP |
| MOUNTING SLOT WIDTH | 0.180 INCHES MINIMUM AND 0.190 INCHES MAXIMUM SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING CURRENT | 50.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING SHIELDING METHOD | CORE GROUNDED SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG AND 2 WIRE LEAD W/LUG |
| TEST DATA DOCUMENT | 28528-1135688 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |